June 15, 2026

Syosset, NY Water Quality Report 2026

By PureWaterGuys

EPA compliance testing (2012–2019) detected 30 regulated contaminants in this water system, including 1 that averaged above a federal limit: Trichloroethylene (TCE), Carbon tetrachloride, 1,1-Dichloroethylene + 27 more.

Unlock the full breakdown — detected levels vs. legal limits, plus what removes each one.

Full contaminant breakdown

EPA Six-Year Review compliance monitoring, 2012–2019 — the most recent national compliance dataset EPA has published. See the sections above for more recent violation and PFAS records.

ContaminantAvg. detectedHighest sampleFederal limitAvg. vs. limit
Trichloroethylene (TCE)EPA health goal: zero 5.18 ppb 19.7 ppb 5 ppb 104% — above
Carbon tetrachlorideEPA health goal: zero 4.21 ppb 9.1 ppb 5 ppb 84%
1,1-Dichloroethylene 5.6 ppb 21.1 ppb 7 ppb 80%
ArsenicEPA health goal: zero 7.19 ppb 11 ppb 10 ppb 72%
1,1,2-Trichloroethane 3.57 ppb 4.44 ppb 5 ppb 71%
Nitrate 3950 ppb 12100 ppb 10000 ppb 40%
1,2-DichloropropaneEPA health goal: zero 1.78 ppb 4.5 ppb 5 ppb 36%
Nitrate + nitrite 3470 ppb 9910 ppb 10000 ppb 35%
Thallium 0.6 ppb 0.79 ppb 2 ppb 30%
Tetrachloroethylene (PCE)EPA health goal: zero 1.31 ppb 6 ppb 5 ppb 26%
Radium (combined)EPA health goal: zero 1.27 pCi/L 2.13 pCi/L 5 pCi/L 25%
Antimony 1.3 ppb 1.77 ppb 6 ppb 22%
Simazine 0.785 ppb 3 ppb 4 ppb 20%
LeadEPA health goal: zero 2.78 ppb 9.1 ppb 15 ppb (action level) 19%
1,2-DichloroethaneEPA health goal: zero 0.846 ppb 1.3 ppb 5 ppb 17%
Chromium (total) 16 ppb 16 ppb 100 ppb 16%
Atrazine 0.357 ppb 0.596 ppb 3 ppb 12%
Beryllium 0.34 ppb 0.34 ppb 4 ppb 8%
PentachlorophenolEPA health goal: zero 0.0495 ppb 0.057 ppb 1 ppb 5%
Selenium 2.31 ppb 2.9 ppb 50 ppb 5%
Copper 54.3 ppb 420 ppb 1300 ppb (action level) 4%
Fluoride 130 ppb 140 ppb 4000 ppb 3%
Total trihalomethanes (TTHMs) 2.3 ppb 4.1 ppb 80 ppb 3%
1,1,1-Trichloroethane 3.22 ppb 8.8 ppb 200 ppb 2%
Nitrite 22.8 ppb 60 ppb 1000 ppb 2%
cis-1,2-Dichloroethylene 0.792 ppb 2.9 ppb 70 ppb 1%
UraniumEPA health goal: zero 0.382 ppb 0.82 ppb 30 ppb 1%
Barium 8.53 ppb 50 ppb 2000 ppb <1%
Ethylbenzene 0.6 ppb 0.6 ppb 700 ppb <1%
Toluene 1 ppb 1.1 ppb 1000 ppb <1%

Also tested, no detections: 1,2,4-Trichlorobenzene, 2,4,5-TP (Silvex), 2,4-D, Alachlor, Benzene, Benzo(a)pyrene, Cadmium, Carbofuran, Chlordane, Chlorobenzene, Cyanide, DBCP, DEHA (adipate), DEHP (phthalate), Dalapon, Dichloromethane, Dinoseb, Dioxin (2,3,7,8-TCDD), Diquat, Endothall, Endrin, Ethylene dibromide (EDB), Glyphosate, Gross alpha radioactivity, Heptachlor, Heptachlor epoxide, Hexachlorobenzene, Hexachlorocyclopentadiene, Lindane, Mercury (inorganic), Methoxychlor, Oxamyl, PCBs, Picloram, Styrene, Toxaphene, Vinyl chloride, o-Dichlorobenzene, p-Dichlorobenzene, trans-1,2-Dichloroethylene.

Reverse osmosis (drinking water)

The treatment category most often matched to dissolved contaminants like lead, arsenic, nitrate, fluoride, and radiological contaminants detected in this system.

Shop reverse osmosis →

Whole-house carbon filtration

The treatment category most often matched to disinfection byproducts (TTHMs, haloacetic acids), chlorine taste and odor, and organic compounds detected in this system.

Shop whole-house systems →

Source: U.S. EPA Six-Year Review 4 compliance monitoring data (2012–2019), the most recent nationwide compliance dataset EPA has released, reported at the water-system level. A detection is not a violation. “Avg. vs. limit” compares the average of laboratory detections to the federal MCL or action level; individual faucets can differ — household plumbing affects lead and copper, and a state-certified laboratory test of your own tap is the only way to confirm levels in your home. Treatment categories are general matches, not a certification claim for a specific product and contaminant.

Water Utility: Jericho Wd
Population Served: 58,000 residents
Data Sources: EPA SDWIS + EPA UCMR5
Report Year: 2026

Syosset, New York drinking water is supplied by Jericho Wd. All US public water systems must test drinking water and report results to the EPA under the Safe Drinking Water Act. This report summarizes health-based violations and PFAS detections recorded in federal databases to help you make informed decisions about home water filtration.

EPA Violation History

No health-based EPA maximum contaminant level (MCL) violations on record since 2010 for this utility.

PFAS "Forever Chemical" Detections

PFAS compounds were detected in this water system during EPA's Fifth Unregulated Contaminant Monitoring Rule (UCMR5) testing program (2023-2025). EPA has set maximum contaminant levels of 4 parts per trillion (ppt) for PFOA and PFOS individually.

PFAS Compound Level Detected Solution
PFBA 0.0059 ug/L PFAS Filters
PFHxA 0.0034 ug/L PFAS Filters
PFPeA 0.0053 ug/L PFAS Filters
PFHpA 0.0038 ug/L PFAS Filters

Source: EPA UCMR5 occurrence data. Levels in micrograms per liter (ug/L = parts per billion). 1 ug/L = 1,000 ppt.

Should You Filter Your Syosset Water?

Even utilities with no EPA violations may have contaminants present below legal limits but above health guidelines. The EPA sets maximum contaminant levels based on what is feasible and affordable to treat at scale -- not necessarily what carries zero health risk. Many independent health organizations recommend filtration for households with children, pregnant women, or immunocompromised individuals regardless of utility compliance status.

Protect Your Syosset Home Water

PureWaterGuys.com carries filtration systems engineered to address the most common contaminants in US tap water. We ship to all New York addresses with free expert guidance on the right system.

Shop Water Filtration Systems →Take the Water Quiz

Filters for Syosset, NY Water Issues

Based on contaminants detected in this report, these systems are worth considering:

⚠️
PFAS / Forever Chemicals
NSF-certified filters proven to remove PFAS, PFOA, PFOS, and 200+ contaminants.
Shop PFAS / Forever Chemicals Filters →
🔬
Arsenic
Whole-house systems with certified arsenic-reduction media.
Shop Arsenic Filters →
💧
Nitrates / Nitrites
Reverse osmosis systems that reduce nitrates to safe levels.
Shop Nitrates / Nitrites Filters →
🏠
Chlorine / Disinfection Byproducts
Whole-house carbon filters that eliminate chlorine taste, odor, and DBPs.
Shop Chlorine / Disinfection Byproducts Filters →

Frequently Asked Questions

Is Syosset tap water safe to drink?

Jericho Wd is required to meet EPA federal drinking water standards. However, meeting legal standards is not the same as being contaminant-free. Trace levels of disinfection byproducts, PFAS compounds, and other regulated contaminants are common in US municipal water systems.

Does Syosset water have PFAS?

PFAS compounds were detected in this utility's water during EPA UCMR5 monitoring. A certified PFAS filter -- such as reverse osmosis or activated carbon block -- can significantly reduce these compounds at your tap.

What water filter works best for Syosset?

A whole-house carbon block filter removes chlorine, chloramines, and many VOCs. For PFAS, arsenic, and nitrates, a reverse osmosis under-sink system provides the highest reduction rates. Take our free 2-minute quiz to find the right system for your home and budget.

Data sourced from EPA SDWIS and UCMR5 federal databases. PureWaterGuys.com is not affiliated with any municipal water utility. Contact your utility's annual Consumer Confidence Report (CCR) for complete local data.

← Back to Water Quality Reports